• -20%
Disolvente Decoración Secado Lento

ANTI FISURAS Additive for CONCRETE AND MORTAR

€29.36 €36.70 -20%
Tax included

CUTTED THREADS TO PREVENT AND CONTROL FITURES IN CONCRETE SUNSHAKES

Fiberglass complement that resists to the concrete alcalis

Material to reinforce concrete slabs, or hydraulic mortar, floors, plasters, to AVOID FRAUDS BY DILATIONS

Fiberglass that provides flexibility to the screeds to avoid cracking as much as possible distributing the loads correctly

KILOS
  • 600 grs


<b>10</b> By purchasing this product, you will accumulate 20 points with our loyalty program. You can convert 20 points in your account into a coupon for a future purchase.

 

CUTTED THREADS from AR GLASS for the control and prevention of concrete cracking.

ANTI-CRAK.- MANUFACTURED FIBERS WITH HIGH CONTENT IN CIRCONIUM THAT COMPLY WITH ASTM C166 / C 1666 / M-07, EN 15422 RULES AND THE RECOMMENDATIONS OF PCI AND GRCA.

.

Fiberglass, which you can use to reinforce the concrete screeds and hydraulic mortars and prevent them from fissuring and souring, is stable to an environment of aggressive calcium oxide.

ANTI CRAK .- (High dispersion), is a cut AR glass, flanked to be incorporated into concrete and any other hydraulic mortar.

.

ADDITIVE FOR MORTARS AND CONCRETE ARE NOT FISSURED AND CRACKED

CHARACTERISTICS, ADVANTAGES AND BENEFITS OF GLASS FIBER TO ADD TO CONCRETE OR MORTAR

- DO NOT RUN. AR fiberglass, is alkali resistant.

- INVISIBLE FIBER ON THE FINISHED SURFACE . As a fiber in AR glass cut yarn, a large number of fibers are released when they are mixed, without the filaments protruding on the surface of the concrete.

- CHECKING AND PREVENTING FISSURE IN FRESH CONCRETE . It has great resistance to traction, so it holds tensions during shrinkage, before the concrete is split.

- It is not dangerous to health, it is SAFE AND EASY TO HANDLE

- HOMOGENEA MIX . The alkaline fiber fibers resembling or AR, reinforce both the plastic and the hardened concrete.

- Global improvement of the durability and mechanical properties of concrete.

- Fiberglass does not absorb water, this fiber basically sews and joins the concrete thanks to its immense tensile strength.

- Fiberglass for concrete or mortar that reinforces the concrete and in the construction of screeds, can replace the electrowelded iron mesh.

- EXCELLENT WORKABILITY . High dispersion: 220 million filaments per Kg (100 million per pound)

- High zirconium content that complies with ASTM C16696 / M-07, EN 15422 and PCI and GRCA recommendations

- EFFECTIVE TO DOSE VERY LOW

.

HOW DO I HAVE TO APPLY THE ADDITIVE OF GLASS FIBER ALCALI RESISTANT ANTI FISURAS, FOR CONCRETE OR MORTARS?

The AR fiberglass cut wires are generally used at a low dosage level to prevent cracking and improve the performance of concrete, floors, plasters and other special mortar mixtures.

It is easily incorporated into the matrix by generating a large number of well-distributed reinforcing fibers from a small amount of product.

Our AR glass fibers can be added to wet concrete in a mixing plant or directly in the concrete mixer truck.

Alkali resistant glass fibers do not protrude on the surface and do not require any additional finishing process. The reinforcement is incorporated in the concrete mada and is invisible on the finished surface.

HOW MANY ADDITIVES ARE ANTIFIXES FOR CONCRETE, CUT FIBERGLASS THREADS, WHAT DO I HAVE TO USE? DOSAGE

PERFORMANCE: 600 GR / M3

A dosing calculation must be carried out according to the characteristics of the subsoil, the dynamic and static stresses that this foundation will have to endure.

It will also influence the amount of glass fiber for concrete to add, the thickness of the slab or tile, the type of concrete we use or the compaction of the subsoil.

Approximately, the fiberglass for concrete or mortar, will be dosed at a rate of 600 gr for each cubic meter (1lb / cu.yd) of concrete for the control of cracking by plastic shrinkage.

.

WHY USE THIS ADDITIVE ANTIFISURES FOR CONCRETE OR HYDRAULIC MORTARS?

When the concrete is poured, the aggregates begin to settle due to gravity forcing the water to the surface.

By adding the secondary additive of CUT GLASS FIBERGLASS, the settling process is altered, because millions of uniformly dispersed fibers produce an internal support system that prevents the precipitation of solids.

The micro fissures or cracks, induced by the effort, are bridged by the cut glass fibers, and thus the propagation of cracks, fissures or cracks is stopped.

This allows the concrete to reach the strength and integrity for which it was designed.

.

PACKAGING AND STORAGE OF THE CUTTED THREADS OF GLASS FIBER FOR CONCRETE

The cut yarns are packaged in individual plastic or paper bags.

Cut fiberglass AR yarns should be stored away from heat and hue.

The best conditions are:

Temperature between 15ºC and -35ºC

Humidity between 35% and -65%

If the cut fiberglass yarns are stored at lower temperatures, it is recommended to condition it in the workshop at least 24 hours before use, to avoid condensation.

STANDARDS OF QUALITY AND CERTIFICATION OF THE CUT GLASS THREADS AR

The fibers are manufactured according to a Quality Management System approved for ISO 9001.

The fibers comply with the safety standards according to the European Directive 99/45 / EC, 67/548 / EEC and its latest tool.

The son cut AR, is subject to evaluation and independent approval in Germany (Zulassung No. Z-3.72.1731)

.

.

CHARACTERISTICS (NOMINAL VALUES) OF CUT GLASS THREADS TO PREVENT CRACKS AND CRACKS IN MORTARS AND CONCRETE

Fiber length: 3; 6; 9; 12: 18 mm - (1 / 8'- 1/4''- 3/8''- 1 / 2''- 3/4 '' inches)

Diameter of filament: 14 (um), 0.000546 (in)

Loss to fire%: 0.55% (ISO 1980: 1980)

Humidity: 0.3% max. (ISO 3344: 1977)

Material: Glass resistant to alcaís

Specific Weight: 2.68 g / cm3

Softening Point: 860 ºC - 1580º F

Electrical conductivity: Very Low

Chemical Resistance: Very High

Modulus of elasticity: 72 GPa. 10 X 10 6 psi

Tensile strength: 1,700 MPa. 250 x 10 3 psi

.

.

.

Fibra alcali resistente
542 Items

You might also like

Customers who bought this product also bought:

Reviews Reviews (3)

Based on 3 reviews - 0 1 2 3 4 5,00/5
0 1 2 3 4
(5/5

Aditivo anti fisuras

Puntuación total: 0 1 2 3 4

Tiene un fácil almacenamiento y me ha sido muy útil para que no se me hagan fisuras en el suelo.
Explica muy bien el modo de empleo así que no he tenido ningún problemaa la hora de usarlo


<b>10</b>
0 1 2 3 4
(5/5

Evitar Grietas en el suelo de cemento

Puntuación total: 0 1 2 3 4

Lo explica muy bien, un producto muy recomendable la verdad, yo lo utilice para evitar las grietas por las vibraciones y muy buen resultado.
No se me ha agrietado el cemento aplicado en la soelra.


<b>10</b>
0 1 2 3 4
(5/5

Prevención fisuras en el cemento

Puntuación total: 0 1 2 3 4

Me ha sido muy útil para prevenir fisuras en una zona donde siempre se me producían fisuras y tra aplicar este producto junto con el cemento, ya no han vuelto a aparecer.


<b>10</b>
Pinterest

Portes Gratis Angar para pedido + 75 €